6222
Two Door Interface
The 6222 Two-door module provides local control for two doors
or a single door with anti-passback. Designed to simplify
the wiring in installations, this module has a built-in power
supply capable of controlling the door hardware.
|
|

• Accepts almost any reader technology
• Built-in Power supply with 12VDC, 2A aux. output, internally
fused
• Wiegand Data Input (5-volt, 32-bit packet, or customized
format)
• REX button connection
• RS485 communication
• Battery leads for charging |
|
Specifications |
|
| Power Requirements |
+ 16VAC 30VA Transformer |
| Auxiliary Power Output |
+12(+0.5/-0.5) VDC, 2.0 AMP Peak 1.5
Amp continuous maximum |
| Auxiliary Power Fuse |
Internally fused, auto-reset |
| Wiegand Data Inputs |
Standard 5-volt Wiegand input, 32-bit
packet or last 32 bits of a 36bit packet |
| Cabling |
Reader to Interface |
Maximum 500 feet, 18 AWG overall shield
(see Reader installation notes for details) |
| |
Interface to Control |
Maximum 4000 feet, Belden #8102,
8132, 9841, or equivalent |
| Operating Environment |
0°C to +50°C (32°F to 122°F)
0% to 95% (no condensing)
Non-weatherized – shield from elements |
| Board Dimensions |
4”W x 5”H x 1.5”D
(102mm x 127mm x 38mm) |
| Case Dimensions |
6.5”W x 8”H x 2.5”D
(166mm x 123mm x 63mm) |
| Case Material |
Beige enamel paint over mild steel |

|
|
|